Units
Metric
Imperial
Test method
Without water jacket
With water jacket
Water in the full cylinder, W
C
Test pressure (gauge)
Water pumped in to reach test pressure, W
B
Water expelled after release, W
E
Water temperature
Compressibility values from
CoolProp
ISO-18119 table
REFPROP
For W
C
, weigh the cylinder empty and full, dried on the outside. Read the burette with the pump piston in the same, back, position every time; a litre of water counts as a kilogram.
Total expansion at test pressure (TE)
cm³
Left in the burette after release (PE)
cm³
Cylinder built to
ISO-9809-1 or ISO-9809-3 (steel)
ISO-9809-2 (high-strength steel)
ISO-7866 (aluminium)
BS-5045 (steel or aluminium)
DOT specification (steel or aluminium)
Not known (ISO-18119)
Rejection limit: permanent expansion at most
% of total
The design standard sets the limit: 10 % for steel to ISO-9809-1 and ISO-9809-3, 5 % for high-strength steel (ISO-9809-2, 1,100 MPa and more) and aluminium (ISO-7866). All parts of BS-5045, steel or aluminium, use 5 %; DOT cylinders, steel or aluminium, are rejected above 10 % at requalification. If the design standard isn't known, ISO-18119 applies 5 %.
Calculate