DOT-3AA plus stamp: Wall check for the 10 % overfill

A US DOT-3AA steel cylinder may be filled to 110 % of its marked service pressure, the famous plus sign after the test date, but only if its wall is thick enough. The rules accept two ways to show that: the thinnest wall measured with an ultrasonic gauge, or the elastic expansion at the hydrostatic test compared with the cylinder’s rejection elastic expansion (REE). The calculator does both, and works out the K-factor from your measurements if you don’t have it.

It covers the wall-stress part of the rule only. The visual inspection and everything else still have to pass on their own.

Background

The 10 % overfill

A DOT-3AA cylinder may be filled to 110 % of its marked service pressure, with a plus sign (+) after the test date, if its wall is thick enough. At heart it is a wall-thickness rule dressed up as a pressure allowance. Instead of a minimum wall for every diameter, 49 CFR 173.302a(b) limits the stress in the wall at test pressure: the average wall stress may not exceed 67,000 psi, or the maximum 73,000 psi. Meeting one of the two is enough. The cylinder still needs a frangible burst disc and has to pass the visual inspection and the water-jacket hydrostatic test; this calculator checks the wall only. The test pressure is 5/3 of the service pressure.

Direct method: the thinnest wall

Find the thinnest spot of the wall with an ultrasonic gauge, minus the paint, and work out the stress there with the Bach formula (49 CFR 178.37). It must stay at or below 73,000 psi:

S = P \cdot \frac{1.3 \cdot D^2 + 0.4 \cdot (D - 2t)^2}{D^2 - (D - 2t)^2}
SWall stress in psi
PTest pressure (gauge) in psi
DOutside diameter in inches
tThinnest wall thickness in inches

Solved for the wall, it gives the thinnest wall that still earns the +, to compare with the ultrasonic readings:

t_\text{min} = \frac{D}{2} \cdot \left( 1 - \sqrt{\frac{S - 1.3 \cdot P}{S + 0.4 \cdot P}} \right)
t_\text{min}Minimum wall thickness in inches
SStress limit in psi: 73,000 for the thinnest wall, 67,000 for the average wall
PTest pressure (gauge) in psi
DOutside diameter in inches

An LP72 (2,250 psi service, 3,750 psi test, 6.83 in diameter) with a thinnest wall of 0.155 in sees about 70,360 psi and qualifies. Its minimum wall is 0.149 in.

Indirect method: elastic expansion

A thin wall expands more under pressure than a thick one, and the water-jacket test measures that expansion accurately. The rejection elastic expansion (REE) is what a cylinder whose average wall just reaches 67,000 psi expands at test pressure, from the Clavarino formula:

REE = P \cdot K \cdot V \cdot 16.387 \cdot \frac{D^2}{D^2 - (D - 2t)^2}
REERejection elastic expansion in cm³
PTest pressure (gauge) in psi
KK-factor of the cylinder design in 1/psi
VWater capacity in in³ (16.387 converts it to cm³)
DOutside diameter in inches
tMinimum average wall in inches, t_\text{min} for 67,000 psi

Bach and Clavarino combine into a single step:

REE = K \cdot V \cdot 16.387 \cdot \frac{S + 0.4 \cdot P}{1.7}
REERejection elastic expansion in cm³
KK-factor of the cylinder design in 1/psi
VWater capacity in in³
SAverage stress limit, 67,000 psi
PTest pressure (gauge) in psi

For the LP72 with a K-factor of 1.19 × 10⁻⁷ per psi and 730 in³ that is 57.4 cm³. If the elastic expansion at the hydrostatic test is larger, the average wall is too thin: no +. This check is separate from the permanent expansion limit, but uses the same readings, since the elastic expansion is the total minus the permanent expansion.

Where the K-factor comes from

The REE belongs to the cylinder design, not to the single cylinder. At best it is stamped on the shoulder; otherwise the manufacturer may have it on file, or the K-factor to work it out. The CGA’s C-5 table lists K-factors, though hardly any for diving cylinders. Failing all that, measure at least three cylinders of the design:

  • the outside diameter D in at least six places, averaged;
  • the wall thickness t on a 3 in grid along the whole sidewall, minus the paint, averaged;
  • the water capacity V, weighing each cylinder three times empty and three times full of water;
  • the elastic expansion EE at test pressure at least three times per cylinder, averaged.
K = \frac{EE \cdot \left( D^2 - (D - 2t)^2 \right)}{P \cdot V \cdot D^2}
KK-factor in 1/psi
EEAverage elastic expansion in cm³
DAverage outside diameter in inches
tAverage wall thickness in inches
PTest pressure (gauge) in psi
VWater capacity in cm³

The formulas work in inches and psi, as the regulations do. The calculator converts metric inputs.

Scroll to Top