Compressor fill rate: What your compressor really delivers

The rated delivery of a compressor was measured on a new machine. Worn piston rings, tired valves or a slipping belt all take their share, and nothing on the compressor tells you how much.

A timed fill does. Fill a cylinder, note the time at regular pressure marks, and the calculator turns that into litres of free air per minute. It allows for air’s real-gas behaviour and the cylinder warming up, and shows the simple pressure-times-volume estimate and, if you enter it, the rated delivery beside it.

Background

How to do a timed fill test

  • Connect the compressor to an empty cylinder of known water capacity and start the compressor.
  • The compressor first has to bring its own stages, separators and filter up to pressure. That air never reaches the cylinder, so don’t time it: start the stopwatch once the cylinder gauge shows a low pressure, say 5 bar (75 psi), and enter that as the first reading at 0:00.
  • Note the time whenever the needle passes a round mark, for example every 20 bar (300 psi), until the cylinder is full. A stopwatch is far more precise than reading a moving needle every minute.
  • Enter the readings and press Calculate. You can paste them straight from a spreadsheet.

Compare the result with the delivery the manufacturer quotes. A worn compressor, leaking valves or a slipping belt show up as a lower fill rate, usually most clearly at high pressure.

The rate of single intervals still scatters a little, because neither gauge nor stopwatch is perfect: on a short interval, a few bar or a couple of seconds make a visible difference. The average over the whole fill is the number that counts.

What the result means

The fill rate is given as free air: litres (or cubic feet) of air at room temperature and sea-level pressure that end up in the cylinder per minute. That is how compressor delivery is usually quoted. For each reading the calculator works out the free air in the cylinder from the real-gas density of air:

V_\text{free} = V \cdot \frac{\rho(p,\ T + \Delta T)}{\rho(p_0,\ T)}
V_\text{free}Free air in the cylinder, at room temperature and sea-level pressure
VWater capacity of the cylinder
\rhoDensity of air from CoolProp
pCylinder pressure, absolute: the gauge reading plus atmospheric pressure
TRoom temperature
\Delta THow much warmer the air in the cylinder is than the room
p_0Sea-level pressure, 1.013 bar

The fill rate between two readings follows from that:

Q = \frac{V_\text{free,end} - V_\text{free,start}}{t}
QFill rate in free air per minute
V_\text{free,end}Free air in the cylinder at the later reading
V_\text{free,start}Free air in the cylinder at the earlier reading
tTime between the two readings in minutes

The simple estimate multiplies the pressure rise by the cylinder volume, as most spreadsheets do. It overestimates the delivery for three reasons: at high pressure air takes up more space than the ideal gas law says (Z-factor above 1), warm air in the cylinder shows a higher pressure than the same air at room temperature, and it counts every bar as one cylinder volume of free air, while free air is measured at 1.013 bar.