Cracking effort is given as a pressure, a few millimetres of water, but it comes from forces: the intermediate pressure pushing the seat open, the bias spring holding it shut, and the lever and diaphragm that let your breath overcome the difference. This calculator follows those forces through an unbalanced or a balanced second stage.
Fill in what you know and leave one field empty; that is the one it works out. Leave the cracking effort empty to get it from the parts, or enter the cracking effort you want and leave the spring, lever or diaphragm empty to see what it takes.
Background
How it works
In a downstream second stage the intermediate pressure (IP) pushes the seat off the orifice, and the bias spring pushes it back. The spring is the stronger of the two; the difference presses the seat into the orifice and keeps the valve shut. When the diver inhales, the pressure in the housing drops: the diaphragm turns that pressure difference into a force, and the lever multiplies it. The cracking effort is the pressure difference at which the valve just starts to open. Ambient pressure is left out, because the IP rises with it.
IP force on the seat
The IP acts on the area of the seat that the orifice encloses:
F_\text{IP} = P_\text{IP} \cdot \left( \frac{d_\text{Orifice}}{2} \right)^2 \cdot \piF_\text{IP}IP force on the seat, in NP_\text{IP}Intermediate pressure (gauge) in N/mm² (1 bar is 0.1 N/mm²)d_\text{Orifice}Orifice diameter in mmIn a balanced second stage the IP also fills the balance chamber and pushes the poppet the other way:
F_\text{IP Chamber} = P_\text{IP} \cdot \left( \frac{d_\text{Chamber}}{2} \right)^2 \cdot \piF_\text{IP Chamber}IP force in the balance chamber, in NP_\text{IP}Intermediate pressure (gauge) in N/mm²d_\text{Chamber}Balance chamber diameter in mmAn unbalanced second stage has no balance chamber, so F_\text{IP Chamber} = 0. The chamber must be smaller than the orifice: a larger one makes an upstream valve, which this calculator doesn’t cover.
Spring force
F_\text{Spring} = K \cdot (L_0 - L)F_\text{Spring}Spring force in NKSpring rate in N/mL_0Relaxed length in mLInstalled length in mNet closing force
F_\text{Net} = F_\text{Spring} - F_\text{IP} + F_\text{IP Chamber}F_\text{Net}Net closing force at the seat, in NF_\text{Spring}Spring force in NF_\text{IP}IP force on the seat, in NF_\text{IP Chamber}IP force in the balance chamber, in NThis force presses the seat into the orifice, and it is what the diver has to overcome. If it is zero or less, the valve free-flows by itself. That happens above this IP:
P_\text{Free-flow} = \frac{F_\text{Spring}}{\left( \frac{d_\text{Orifice}}{2} \right)^2 \cdot \pi - \left( \frac{d_\text{Chamber}}{2} \right)^2 \cdot \pi}P_\text{Free-flow}IP (gauge) at which the valve opens by itself, in N/mm²F_\text{Spring}Spring force in Nd_\text{Orifice}Orifice diameter in mmd_\text{Chamber}Balance chamber diameter in mm (0 if unbalanced)Lever
The lever’s advantage is the ratio of its two arms:
\text{Lever advantage} = \frac{X}{Y}\text{Lever advantage}How many times the lever multiplies a forceXLong lever arm in mmYShort lever arm in mmIt reduces the force needed at the long arm:
F_\text{Long lever} = \frac{F_\text{Net}}{\text{Lever advantage}}F_\text{Long lever}Force at the long arm, in NF_\text{Net}Net closing force at the seat, in N\text{Lever advantage}Long lever arm divided by the short lever armDiaphragm
Only part of the diaphragm works: its effective diameter lies between the clamped rim and the backing plate.
D_\text{Effective} = \frac{D_\text{Clamped} + D_\text{Plate}}{2}D_\text{Effective}Effective diaphragm diameter in mmD_\text{Clamped}Clamped diaphragm diameter in mmD_\text{Plate}Backing plate diameter in mmSpread over that area, the force at the long arm becomes the cracking effort:
P_\text{Cracking} = \frac{F_\text{Long lever}}{\left( \frac{D_\text{Effective}}{2} \right)^2 \cdot \pi}P_\text{Cracking}Cracking effort in Pa (N/m²)F_\text{Long lever}Force at the long arm, in ND_\text{Effective}Effective diaphragm diameter in m| Unit | In pascal |
|---|---|
| 1 mmH₂O | 9.8067 Pa |
| 1 inH₂O | 249.09 Pa |
| 1 mbar | 100 Pa |
Working out any value
Put together, the forces on the poppet balance like this. The calculator rearranges it for the field you leave empty, and every value has exactly one answer:
\begin{aligned} & K \cdot (L_0 - L) \\ & = P_\text{IP} \cdot \left( \frac{d_\text{Orifice}}{2} \right)^2 \cdot \pi \\ & - P_\text{IP} \cdot \left( \frac{d_\text{Chamber}}{2} \right)^2 \cdot \pi \\ & + P_\text{Cracking} \cdot \left( \frac{D_\text{Effective}}{2} \right)^2 \cdot \pi \cdot \frac{X}{Y} \end{aligned}KSpring rate in N/mL_0Relaxed length in mLInstalled length in mP_\text{IP}Intermediate pressure (gauge) in Pad_\text{Orifice}Orifice diameter in md_\text{Chamber}Balance chamber diameter in m (0 if unbalanced)P_\text{Cracking}Cracking effort in PaD_\text{Effective}Effective diaphragm diameter in mXLong lever arm in mYShort lever arm in mFor the diaphragm, the calculator first finds the effective diameter and then the clamped or backing plate diameter from the other one.
Example
The unbalanced example values: 9.5 bar on a 5.0 mm orifice opens with 18.65 N. The spring, 2,300 N/m and 22.5 mm long, compressed to 10.9 mm, closes with 26.68 N, so 8.03 N net. The 24 to 1.85 mm lever (12.97) brings that down to 0.62 N. A 62 mm diaphragm with a 26 mm backing plate works with 44 mm: 407 Pa, or 41.5 mmH₂O. The balanced example has a 4.2 mm balance chamber and a lighter spring (2,306 N/m, 23 mm compressed to 18.3 mm): 35.1 mmH₂O.
How to measure
- Orifice diameter: measure the orifice with a calliper.
- Balance chamber diameter: the diameter of the bore in which the poppet’s O-ring runs.
- Spring rate and relaxed length: with a kitchen scale and a calliper, using the Spring constant calculator.
- Installed length: the spring’s length in the assembled valve, closed, with the lever up. Measure it on a cutaway, or work it out from the dimensions of the parts.
- Lever arms: from the pivot, square to the direction of each force: X to where the diaphragm presses, Y to the line along which the poppet pulls.
- Diaphragm: the diameter where the housing grips its rim, and the diameter of the backing plate.
Limits
The result is an ideal balance of forces. Friction at the lever’s pivot and contact points, the stiffness of the diaphragm and a seat that has settled into the orifice all add a little, so a real second stage cracks slightly harder. The effective diameter as the average of the two diameters is good to about 5 %. The cracking effort is the one set on the bench; in the water, the height of the exhaust valve above the diaphragm sets a lower limit: see the Minimum cracking effort calculator.