Service manuals give cracking effort in whatever unit the maker preferred: millimetres or inches of water, millibar or pascal. Enter the figure from the manual in the unit it uses to see it in the other three, and whether it sits inside the usual range.
Most second stages are set between about 2.5 and 4.2 mbar, which is roughly 1.0 to 1.7 inches of water.
Background
The units
The cracking effort is a small pressure: how far the pressure inside the second stage has to drop below the water pressure before the valve opens. Service manuals give it as a column of water, in millimetres or inches, or in millibar or pascal.
A column of water becomes a pressure with:
p = \rho \cdot g \cdot hpPressure in Pa\rhoDensity of water, 1,000 kg/m³g9.8067 m/s²hHeight of the water column in m| Unit | In pascal |
|---|---|
| 1 mmH₂O | 9.8067 Pa |
| 1 inH₂O | 249.09 Pa |
| 1 mbar | 100 Pa |
One inch of water is 25.4 mmH₂O, and one millibar is about 10.2 mmH₂O.
The usual range
Most second stages are set between about 2.5 and 4.2 mbar, or 1.0 to 1.7 inH₂O; the table marks that range. A value is counted as inside when it rounds to 2.5 to 4.2 mbar, so 1.0 inH₂O (2.49 mbar) is in and 1.8 inH₂O (4.48 mbar) is out.
The range is a guide only. The figure in the service manual for the model is the one to set.