Fitting a new motor, swapping an electric drive for a petrol engine, or building a compressor from parts? The calculator estimates the shaft power a multi-stage breathing-air compressor needs for its delivery and final pressure, the current an electric motor draws on single- or three-phase supply, and the pulley size that brings the block to its design speed.
The work of each stage comes from the real-gas properties of air, and the default efficiency is set against the motors the makers actually fit.
Background
How the power is calculated
The compressor pushes the air through several stages, each raising the pressure by the same factor, with an intercooler after each one. For every stage the calculator takes the work of an ideal, loss-free compression from CoolProp’s real-gas properties of air and divides it by the compressor efficiency. More stages mean less work, because the air is cooled in between.
P = \frac{\dot m}{\eta} \sum_{i=1}^{n} \left( h_{s,\text{out},i} - h_{\text{in},i} \right)PShaft power in W\dot mMass of air delivered per second, in kg/s\etaCompressor efficiencynNumber of stagesiStage numberh_{s,\text{out},i}Enthalpy of the air at the outlet of stage i after an ideal (isentropic) compression, in J/kgh_{\text{in},i}Enthalpy of the air at the inlet of stage i, in J/kgEach stage raises the pressure by the same ratio:
r = \left( \frac{p_\text{out}}{p_\text{in}} \right)^{1/n}rPressure ratio of each stagep_\text{out}Final pressure, absolutep_\text{in}Intake pressure, absolutenNumber of stagesEfficiency of the compressor
This is the isentropic efficiency: the ideal, loss-free compression work divided by the work the shaft really has to deliver. It covers friction, valve losses and heat. Working back from the motors manufacturers fit gives about 55–65 %: Bauer puts a 2.2 kW motor on the Junior II (100 L/min, 3 stages, up to 330 bar) and 7.5 kW on the Mariner 320 (320 L/min, 4 stages, up to 350 bar). 60 % is a sound default. If you know the motor fitted to a compressor like yours, adjust the efficiency until the shaft power matches it.
Motor current
The motor draws more electrical power than it delivers at the shaft, and the power factor raises the current further:
I_{1\sim} = \frac{P}{\eta_\text{m} \cdot U \cdot \cos\varphi}I_{1\sim}Current of a single-phase motor in APShaft power in W\eta_\text{m}Motor efficiencyUMains voltage in V\cos\varphiPower factor of the motorand for a three-phase motor:
I_{3\sim} = \frac{P}{\eta_\text{m} \cdot \sqrt{3} \cdot U \cdot \cos\varphi}I_{3\sim}Current in each phase of a three-phase motor, in APShaft power in W\eta_\text{m}Motor efficiencyUVoltage between two phases in V\cos\varphiPower factor of the motorEfficiency (\eta_\text{m}) and power factor (\cos\varphi) are printed on the motor’s rating plate. Single-phase motors of this size reach roughly 70–80 %, modern three-phase motors (efficiency class IE3) around 88–91 % between 4 and 11 kW. The power factor is usually 0.8–0.9.
Choosing a motor or engine
Pick a motor whose rated power is at least the shaft power shown. Petrol and diesel engines are rated at their peak power; choose one whose continuous power covers the shaft power. Belt drives lose a few percent on top.
Pulley size
The belt runs at the same speed on both pulleys, so pulley diameter times speed is the same on both sides:
d_\text{motor} = d_\text{compressor} \cdot \frac{n_\text{compressor}}{n_\text{motor}}d_\text{motor}Diameter of the motor pulleyd_\text{compressor}Diameter of the compressor pulleyn_\text{compressor}Speed of the compressor in rpmn_\text{motor}Speed of the motor in rpm