Flow bench graphs: Dynamic flow effort and intermediate pressure

A static cracking test only shows where a second stage opens. A flow bench shows what happens once gas is moving: how the effort builds, when the Venturi kicks in and how far the IP drops. A clogged filter or a restricted hose shows up here even when the cracking effort looks fine.

Enter your readings for a complete regulator, a second stage or a first stage, up to three runs. The calculator plots effort and IP against flow, works out the IP drop and the effort rise, flags patterns worth a closer look and prints the lot as a PDF test report. The EN-250 limits are drawn as a reference, not as a pass or fail.

Background

What the page does

It plots flow-bench readings: the flow effort the second stage needs, and the intermediate pressure (IP) the first stage holds, at each flow. The shape of the curves tells you more than any single number, so compare the runs and look for the patterns below.

On a complete regulator, note the IP every time you note the flow effort: each row then has both. A second stage tested alone has only the flow effort, a first stage alone only the IP.

How to measure

The test chain is: first stage → IP gauge → second stage → differential pressure gauge → flow meter → suction source. Set each flow on the suction side, let the flow meter settle, then read the effort on the differential pressure gauge and the IP on the IP gauge.

  • Common test points are 70, 140, 210, 280, 350 and 420 L/min (steps of 2.5 cfm), or 5, 7.5, 10 and 12.5 SCFM.
  • Run the flow test at a low supply pressure, about 35–40 bar (500–600 psi): it is the worst case for the first stage.
  • With an adjustable Venturi, do one run at minimum and one at maximum.

The bench’s instruments are often marked in other units:

InstrumentUnitEquals
Flow meter1 m³/h16.667 L/min
Flow meter1 cfm28.317 L/min
Pressure gauge1 inH₂O25.4 mmH₂O
Pressure gauge1 mbar10.197 mmH₂O

Static values

The static cracking effort is the suction at which the valve just opens; it is the first point of the effort graph, at zero flow. The static IP is the lockup pressure once it has settled; it is the first point of the IP graph and the reference for the IP drop. Both come from the low-supply column, because the flow test runs at low supply. Fill in the zero-flow row of the table to use other values for a run.

Values worked out

The rise of the flow effort over the static cracking effort:

\Delta E = E - E_\text{static}
\Delta EEffort rise in mmH₂O
EFlow effort at this flow, in mmH₂O
E_\text{static}Static cracking effort in mmH₂O

The IP drop at a flow:

\Delta P_\text{IP} = P_\text{static} - P_\text{dynamic}
\Delta P_\text{IP}IP drop in bar
P_\text{static}Static IP (gauge) in bar
P_\text{dynamic}Dynamic IP (gauge) at this flow, in bar

The same drop as a share of the static IP:

\text{Drop} = \frac{\Delta P_\text{IP}}{P_\text{static}} \cdot 100
\text{Drop}IP drop in %
\Delta P_\text{IP}IP drop in bar
P_\text{static}Static IP (gauge) in bar

A Venturi assist that crosses zero crosses over into positive pressure. The crossover flow is found between the last reading above zero and the first at or below it:

Q_\text{cross} = Q_1 + (Q_2 - Q_1) \cdot \frac{E_1}{E_1 - E_2}
Q_\text{cross}Crossover flow in L/min
Q_1Last flow with the effort above zero, in L/min
Q_2First flow with the effort at or below zero, in L/min
E_1Flow effort at Q_1, in mmH₂O
E_2Flow effort at Q_2, in mmH₂O

Reading the graphs

  • Without a Venturi assist the effort rises with flow: the lever opens further against the bias spring, and the losses in seat, hose and mouthpiece increase as the flow increases.
  • With a Venturi assist the effort falls with flow and may cross zero. Above zero the diver pulls a suction; below zero the moving gas holds the lever down.
  • The IP drops as the flow rises. The larger the flow, the larger the drop that is acceptable; some service manuals give a limit.

Advisory flags

The page points out these patterns. They are hints, not pass or fail: service manuals give no flow-effort limits.

  • Flow effort above about 100 mmH₂O (4 inH₂O): well above that at moderate flow points to a restriction in the second stage or hose, or to a first stage that can’t keep up.
  • IP drop of more than 2 bar (29 psi): a healthy first stage stays below about 2 bar; 2–3 bar or more points to a problem, such as a clogged filter or a worn high-pressure seat.
  • Flow effort above 25 mbar (255 mmH₂O, 10.04 inH₂O): the EN-250 limit for the peak pressure during inhalation.
  • Positive pressure of more than 5 mbar (51 mmH₂O, 2.01 inH₂O): the EN-250 limit for a positive pressure during inhalation. Brief spikes may reach 10 mbar (102 mmH₂O, 4.01 inH₂O).

The effort graph shows the EN-250 limits as dashed lines once the readings come near them. EN-250 measures on a breathing simulator at 6 bar in water, so on this bench the lines are a reference, not a compliance test.

Limits

A flow bench works at atmospheric pressure. At depth the gas is denser and flows differently, so these numbers are not dive performance: use them for trends, for comparing runs and for finding faults such as a blocked gas path. The IP gauge sits on a port next to the hose, so the gas flowing past drags its reading a little: small differences between regulators mean little.