A second stage can’t be set to any cracking effort you like. When the exhaust valve sits higher in the water than the inhalation diaphragm, it feels less water pressure, and if the cracking effort is too low, gas bubbles out of the exhaust while new gas flows in: the second stage free-flows.
That pressure difference between the inhalation diaphragm and the exhaust valve changes as the second stage is rotated in the water. It is called the rotational pressure differential, or RPD; some literature calls it the case geometry fault.
This calculator gives the lowest cracking effort that prevents a free-flow in any position. It starts from the distance between the centre of the inhalation diaphragm and the far rim of the exhaust diaphragm, then takes off half the height of the inhalation diaphragm and a little for the stiffness of the exhaust diaphragm, as both work in your favour. Enter your second stage’s cracking effort as well to see whether it is high enough.
Background
What it does
Two parts of a second stage respond to the water pressure: the inhalation diaphragm and the exhaust diaphragm. Even on the small scale of a second stage the water pressure is not the same everywhere: the uppermost part feels less than the lowermost. The pressure difference between the two diaphragms therefore changes as the second stage is rotated in the water. This is the rotational pressure differential, or RPD; some literature calls it the case geometry fault.
When the exhaust diaphragm sits higher in the water than the centre of the inhalation diaphragm, it feels less water pressure. If the cracking effort is smaller than that difference, gas escapes through the exhaust while the inhalation valve lets new gas in: the second stage free-flows. The calculator gives the lowest cracking effort that prevents this in any position.
The formulas
The inhalation valve opens when the pressure in the housing has dropped by the cracking effort below the water pressure at the centre of the inhalation diaphragm:
P_\text{Internal} = P_\text{Reference} - P_\text{Cracking}P_\text{Internal}Pressure in the housing when the valve opens, in PaP_\text{Reference}Water pressure at the centre of the inhalation diaphragm, in PaP_\text{Cracking}Cracking effort in PaThe water pressure at the highest point of the exhaust diaphragm’s rim, a height h above that centre, is lower:
P_\text{Exhaust} = P_\text{Reference} - \rho \cdot g \cdot hP_\text{Exhaust}Water pressure at the highest point of the exhaust diaphragm, in PaP_\text{Reference}Water pressure at the centre of the inhalation diaphragm, in Pa\rhoDensity of the water in kg/m³g9.8067 m/s²hHeight of the exhaust diaphragm’s rim above the diaphragm centre, in mThe exhaust stays shut as long as P_\text{Internal} is not above P_\text{Exhaust}. That gives the minimum cracking effort:
P_\text{Cracking,min} = \rho \cdot g \cdot hP_\text{Cracking,min}Minimum cracking effort in Pa\rhoDensity of the water in kg/m³g9.8067 m/s²hHeight of the exhaust diaphragm’s rim above the diaphragm centre, in m| Unit | In pascal |
|---|---|
| 1 mmH₂O | 9.8067 Pa |
| 1 inH₂O | 249.09 Pa |
| 1 mbar | 100 Pa |
A cracking effort gauge reads millimetres of fresh water. In fresh water every millimetre of height therefore needs 1 mmH₂O of cracking effort, in salt water of 1,025 kg/m³ it needs 1.025 mmH₂O.
| Water | Density |
|---|---|
| Fresh water | 1,000 kg/m³ |
| Baltic Sea | about 1,005 kg/m³ |
| Most seas | 1,025 kg/m³ |
| Red Sea | about 1,030 kg/m³ |
The worst position
Turning the second stage cannot change the distance between the centre of the inhalation diaphragm and the far rim of the exhaust diaphragm: it is built into the housing. Turning only decides how much of that distance stands upright, and only the upright part is a difference in depth.
The height h is largest when the far rim of the exhaust diaphragm lies exactly above the centre of the inhalation diaphragm, on many designs a little further round than face-down. Then h equals the distance A, so that distance covers every position.
How to measure
Take the cover and the inhalation diaphragm off. The lever sits right under the diaphragm’s disc, so its top stands in for the centre of the diaphragm. Measure with a calliper in a straight line from just above the lever to the far rim of the exhaust diaphragm.
If the exhaust diaphragm sits in the middle of the inhalation diaphragm, a coaxial exhaust, the distance is the exhaust diaphragm’s radius.
Diaphragm height and exhaust
Beyond the water itself, there are two more caveats. The exhaust diaphragm is not weightless; it carries a little resistance of its own. And the reference point used so far is a bit of a cheat: the true one does not sit on the face of the inhalation diaphragm at all, but in an imagined plane cutting through it. Both pull in the same direction, and that direction is in your favour.
The calculator takes the height of the inhalation diaphragm, meaning how far its dome stands proud, halves it and deducts that from the measured distance. Then it takes off another couple of millimetres for the exhaust diaphragm’s stiffness. In the formula for the minimum cracking effort, h becomes:
h = A - \frac{H}{2} - ehHeight used for the minimum cracking effort, in mADistance measured from the centre of the inhalation diaphragm to the far rim of the exhaust diaphragm, in mHHeight of the inhalation diaphragm: how far its dome stands proud of the rim, in meAllowance for the exhaust diaphragm’s stiffness: 0.002 m soft, 0.004 m medium, 0.006 m firmLimits
Salt water is denser than fresh water, which is why 40 mm of height asks for 41 mmH₂O in water of 1,025 kg/m³. A setting for salt water also covers fresh water.
The deductions for the diaphragm height and the exhaust are rules of thumb. If the stiffness of the exhaust diaphragm is unknown, Soft takes the least off and gives the cautious figure.
The result is an estimate for a second stage without a service manual, not a replacement for the maker’s figure.
This is not the only factor at play. Some designs, such as a coaxial exhaust, would allow tiny cracking efforts by this measure, but a second stage set that low becomes so touchy that it is unusable: small movements or handling start the gas flowing. In practice even these designs are set no lower than about 25 mmH₂O.