Compressor filter cartridge lifetime

Every compressor filter cartridge has a limited life. Once the molecular sieve is saturated, moisture gets through and the air no longer meets the breathing-air standard. The calculator estimates how many hours a cartridge lasts on your compressor and how many cylinders it fills in that time.

The method is the one the makers use: the air reaches the filter saturated with water and a little warmer than the room, and the sieve takes up about a fifth of its own weight in water. Room temperature and tower pressure decide the rest. Enter the cartridge price as well to get the cost per fill.

Background

Where the water goes

The saturation vapour pressure of water depends on temperature only, not on pressure. Compressing the air drives the water’s partial pressure far above it, so at every intercooler everything above that ceiling condenses and the separators drain it off. Whatever the humidity of the intake air, it reaches the filter saturated, at 100 % relative humidity and the temperature of the final separator: typically about 15 °C above the room. Humidity only changes how much the separators collect; temperature decides what the filter gets.

The cartridge’s molecular sieve takes up the rest. It holds about 20 % of its own weight in water, and water is almost always what uses up a cartridge first. The activated carbon and hopcalite are not part of this calculation.

How much water reaches the filter

The saturation vapour pressure, with the Tetens equation:

SVP = 610.94\ \text{Pa} \cdot 10^{\,7.5 \cdot T / (237.3 + T)}
SVPSaturation vapour pressure in Pa
TTemperature of the air at the filter in °C: room temperature plus warm-up

From the ideal gas law, the water in every cubic metre of saturated air in the tower:

\frac{m}{V} = 2.16679\ \frac{\text{g} \cdot \text{K}}{\text{J}} \cdot \frac{SVP}{T}
m/VWater in g per m³ of air in the tower
SVPSaturation vapour pressure in Pa
TTemperature of the air at the filter in kelvin

Each cubic metre in the tower holds p cubic metres of free air, so per cubic metre the compressor delivers:

w = \frac{m/V}{p}
wWater in g per m³ of free air
m/VWater in g per m³ of air in the tower
pMean pressure in the filter tower (gauge) in bar

How long the cartridge lasts

t = \frac{m_s \cdot a}{Q \cdot w}
tLifetime in hours
m_sMolecular sieve in g
aWater uptake of the sieve, about 0.2
QCompressor delivery in m³ of free air per hour
wWater in g per m³ of free air

A Bauer P21 (68 g sieve) on a 100 L/min compressor at 20 °C: the air at the filter is 35 °C, SVP = 5,624 Pa and the tower air holds 39.5 g/m³. At 160 bar that is 0.247 g per m³ of free air, or 1.48 g an hour, so the 13.6 g the sieve takes up last 9.2 hours.

The pressure in the filter tower

The pressure maintaining valve keeps the tower at its setting until the cylinders pass it; from there the tower follows the cylinder pressure. Every cubic metre of air carries water in proportion to 1/p, so the mean has to be taken over the air, not over time. With the returned cylinders below the valve setting:

\bar{p} = \frac{p_f - p_r}{\dfrac{p_v - p_r}{p_v} + \ln \dfrac{p_f}{p_v}}
\bar{p}Mean pressure in the filter tower (gauge)
p_fFill pressure (gauge)
p_rPressure left in the returned cylinders (gauge)
p_vSetting of the pressure maintaining valve (gauge)

For fills from 50 to 200 bar with the valve at 150 bar that is 157 bar, close to the 160 bar Bauer suggests for 200 bar fills (180 bar for 300 bar fills). The calculator fills it in from your fill and lets you adjust it.

What it leaves out

Real compressed air holds more water than the ideal gas law says: about 1.3 times as much at 100 bar, 1.6 times at 160 bar and 1.8 times at 200 bar. The manufacturers calculate without it, and their lifetimes are the ones shops work with, so this calculator does the same. The warm-up depends on the compressor’s cooling and the room’s ventilation. Treat the result as a guide, and replace the cartridge early rather than late.