The hydrostatic test shows whether a cylinder’s wall still stretches and springs back, or has started to yield. With a water jacket the expansion is read straight off the burette or scale. Cylinders too big for a jacket are tested by measuring the water pumped in and let out again, but water compresses at test pressure, and a good part of what you pump in never reaches the cylinder wall.
The calculator corrects for the compressed water, gives the permanent expansion as a share of the total and checks it against the limit of the standard the cylinder was made to.
Background
Two ways to measure the expansion
The cylinder is pressurised with water, not gas: water hardly compresses, but hardly is not the same as not at all. The test pressure is stamped on European cylinders, 3/2 of the working pressure for scuba; in the US it is 5/3 of the service pressure.
- Volumetric expansion with a water jacket: the cylinder sits in a jacket full of water, and the water it displaces as it stretches runs into a burette. The reading at test pressure is the total expansion; what stays in the burette after release is the permanent expansion.
- Volumetric expansion without a jacket: for cylinders too big for a jacket, such as bank cylinders. You measure the water you pump in and the water that comes back.
Either way the result is the permanent expansion as a share of the total:
PE\% = \frac{PE}{TE} \cdot 100PE\%Permanent expansion in percent of the totalPEPermanent expansion in cm³TETotal expansion at test pressure in cm³Steel to ISO-9809-1 and DOT cylinders may reach 10 %, aluminium to ISO-7866 only 5 %: steel has a clear yield point and work-hardens, aluminium yields gradually and cracks more easily. In practice most cylinders show little or no permanent expansion at all.
Testing without a jacket
Weigh the cylinder empty and full to find how much water it holds, W_C. Fill the cylinder and the burette with no air left in the system. Pump water in up to test pressure and read off the burette how much it took, W_B. Release the pressure and read how much flows back, W_E. The pitfalls:
- Bleed the air through a valve close to the cylinder, at about a third of the test pressure.
- The pump’s check valves only let water one way: the water needs a bypass line back to the burette, with an isolating valve, and a second isolating valve just after the pump.
- Single-acting pumps draw in water on the return stroke. Always read with the piston in the same, back, position.
- At several hundred bar water compresses noticeably. Much of
W_Bonly makes up for that and never reaches the cylinder wall.
Correcting for the water
All the water in the cylinder is compressed, not just what you pumped in. The volume this takes up:
C = m \cdot P \cdot \left( K - \frac{0.68 \cdot P}{10^5} \right)CVolume correction in cm³mMass of all the water in the cylinder at test pressure, in kgPTest pressure (gauge) in barKCompressibility factor of water at its temperature, in cm³/(kg·bar)with the water in the cylinder at test pressure:
m = W_C + W_BmMass of all the water in the cylinder at test pressure, in kgW_CWater in the full cylinder, in kgW_BWater pumped in to reach test pressure, in kgThe ISO-18119 table gives K from 6 to 26 °C; CoolProp and REFPROP give very similar values. Between whole degrees the calculator interpolates. The cylinder’s expansion follows, with 1 kg of water taken as 1,000 cm³:
TE = W_B - CTETotal expansion in cm³W_BWater pumped in to reach test pressure, in cm³CVolume correction in cm³PE = W_B - W_EPEPermanent expansion in cm³W_BWater pumped in to reach test pressure, in cm³W_EWater expelled after release, in cm³The permanent expansion needs no correction, because it is read at atmospheric pressure. Take a 100 L bank cylinder holding 101.6 kg of water at 15 °C, tested at 232 bar: 1.532 kg goes in, 1.485 kg comes back. Uncorrected that is 3.07 %, a pass. But 1,082 cm³ only compressed the water, so the true total expansion is 450 cm³ and the permanent expansion 10.4 %: a fail under every standard.